This document provides detailed specifications for the B80SE3-AU model of the PowerLink series generator sets. It covers various aspects such as design standards, environmental operating conditions, factory inspections, painting process, general features, equipment specifications, control systems, and overall dimensions.
B80SE3-AU
Standards & Conditions
- Design Standards: Adheres to Conformite Europeenne (CE), ISO8528-5:2005, AS 3000-2018, AS 3010-2017.
- Environmental Operating Conditions: Suitable for outdoor or indoor (well-ventilated) installations, operating in temperatures ranging from -25℃ to 45℃, humidity below 90%, and at altitudes below 1000 metres.
- Factory Inspection: Includes inspection items, protection devices working test, starting ability in normal temperature, load moment capability, and voltage deviation/speed variation tests.
- Painting Process: Specifications and colour options based on the manufacturer’s standard, with customization available.
General Features
- Engine and Alternator: Baudouin engine 4M10G4D3/5, coupled with Leroy Somer alternator LSA44.3S3.
- Control Module: Microprocessor control module PLC-7420.
- Additional Features: ABB main circuit breaker, speed governor, excitation system, AVR Model R250, key switch, emergency stop switch, ATS receptacle, remote run connector, maintenance-free battery, and various safety and operational features.
Equipment Specification
- Technical Data:
- Model: B80SE3-AU
- Tank capacity: 530L
- Dry weight: 1831kg
- Noise level @7m: 68.6dBA
- Dimensions: 2788x1165x1900mm
- Power: Standby Power 88kVA/70kW, Prime Power 80kVA/64kW
- Voltage options: 380V, 400V, 415V
- Diesel Engine Specifications:
- Manufacturer: Baudouin
- Model: 4M10G4D3/5
- Dimensions, weight, number of cylinders, bore, stroke, displacement, compression ratio, injection type, intake system, cooling system, battery voltage, fuel and oil type, capacities, back pressure, power ratings, and fuel consumption details.
- Alternator Specifications:
- Manufacturer: Leroy Somer
- Model: LSA44.3S3
- Exciter type, cooling fan, windings, insulation class, winding pitch, terminals, drip proof rating, altitude limit, overspeed limit, air flow, voltage regulation, harmonic specifications, telephone interference.
Control System
- PLC-7420 Control System:
- Advanced microprocessor control for protection and monitoring.
- Capabilities include monitoring operational parameters, indicating status and fault conditions, multiple protections, display features, manual/automatic/remote work mode, real-time clock, overall power output display, speed/frequency detection, and PC communication via RS485 or RS232 using MODBUS protocol.